| 125 Hp ECVRT-125-46 Dual Source Transfer Switch Variable Speed Controller with Primary Reactor Reduced Voltage Starting in By-Pass Mode with 5% Line Reactor and D.C. Link Reactor - for - University Campus Building (Sprinkler Retrofit) |
|
| ---- Job Site Photos ---- | |
| |
Mid Rise University Building (161 KBytes) |
| |
Three Bay - ECVRT-125-46 and PumpView (159 KBytes) |
| 100 Hp ECVRT-100-46 Dual Source Transfer Switch Variable Speed Controller with Primary Reactor Reduced Voltage Starting in By-Pass Mode with 5% Line Reactor and D.C. Link Reactor - for - University Campus Building (Sprinkler Retrofit) |
|
| ---- Job Site Photos ---- | |
| |
Low Rise UniversityBu ilding (136 KBytes) |
| |
Three Bay - ECVRT-100-46 and Pump View (90 KBytes) |
|
|
Fire Pump Motor & Discharge Piping (with Jim's Laptop) (273 KBytes) Note Bypass Relief Valve and Suction Supply Pump Bypass. |
|
|
Fire Pump & Motor Detail and Jockey Pump (78 KBytes) |
| 100 Hp ECV-100-46 Variable Speed Fire Pump Controller - with - A-T-L (Full Voltage) Starting in By-Pass Mode with 5% Line Reactor and D.C. Link Reactor - for - Mulit-Building High Rise Condominium Development |
|
| ---- Job Site Photos ---- | |
| |
Construction Cranes (421 KBytes) |
| |
Pump House Exterior View (210 KBytes) |
|
|
Model ECV Controller - Open Door View (116 KBytes) |
|
|
Fire Pump & Motor Detail and Jockey Pump (197 KBytes) |
| ---- Job Site Photos ---- Variable Speed Motor Drive and Engine Drive Fire Pumps - and - Variable Speed Jockey / Make-up Pump - for - Dual Use Fire and Domestic Water on Large Multi-Building Industrial Facility. Note: All Three Controllers include Low Suction Pressure Alarm |
|
|
125 Hp ECV-125-46 Variable Speed Fire Pump Controller - with - A-T-L (Full Voltage) Starting in By-Pass Mode with 5% Line Reactor and D.C. Link Reactor in NEMA 12 Enclosure |
|
| |
ECV-125-46 Open Door View (564 KBytes)
Note: Controller includes both Digital and Mercoid Pressure Switches. |
| |
SRAP-12 and ECV Detail View (96 KBytes) Note: SRAP-12 Alarm Set Monitors Tamper Switches to send alarm the ECV. The ECV then signals the central station. Additional Plumbing includes Suction Pressure Alarm and Weekly Test equipment. |
|
|
125 Hp Motor Driven Pump (157 KBytes) Notice Main Relief Valve with Waste Cone. Also note Recirculation Relief Valve. Also Notice The Flow Meter Higher Resolution Image (314 KBytes) Still Higher Resolution Image (515 KBytes) |
|
Model DCFRA Variable Speed Diesel Fire Pump Controller - with - System Overpressure Pressure Switch and Alarm. |
|
|
|
Model DCFRA Variable Speed Fire Pump Controller (103 KBytes) Note: Controller includes System Overpressure Pressure Switch and Alarm. |
|
|
Variable Speed Diesel Driver (145 KBytes) |
|
Model SPXV-15-46 Variable Speed Pump Jockey Controller Note: NEMA 12 Non-vented Construction, with Heat Pipe Technology Air-to-Air Cooler, and with Model PR4001 Paperless Pressure and Alarm Recorder - with - System Overpressure Pressure Switch and Alarm -for- Combination Jockey Pump and Domestic Water Make-up Booster Pump |
|
|
|
Model SPXV-15-46 Variable Speed Pump Controller (119 KBytes) |
|
|
15 Hp Jockey Pump (149 KBytes) Higher Resolution Image (293 KBytes) Note Both Relief Valves for Both Fire Pumps (one each to Waste and one Each Recirculate). |
|
|
All Three Pumps (147 KBytes) Higher Resolution Image (303 KBytes) Still Higher Resolution Image (493 KBytes) |
| 125 Hp ECVRT-125-46 Dual Source Transfer Switch Variable Speed Controller with Primary Reactor Reduced Voltage Starting in By-Pass Mode with 5% Line Reactor and D.C. Link Reactor in NEMA 12 Enclosure - for - Major Airport Rental Car Center Facility |
|
| ---- Job Site Photos ---- | |
| |
Rental Car Center Facility Structure (43 KBytes) |
| |
Three Bay - ECVRT-125-46 Closed Door View (105 KBytes) |
|
|
Fire Pump Motor (118 KBytes) |
| 250 Hp ECV-250-46
Full Voltage Starting in By-Pass Mode With 5% Line Reactor and D.C. Link Reactor in NEMA 12 Enclosure Protecting a 1.6 Million Square Foot Distribution Center 310 Acre site with 348 miles of fire protection piping. |
|
| ---- Factory Build Photos ---- | |
| |
Closed Door View (176 KBytes) |
| |
Open Door View (138 KBytes) |
| |
Same View with Annotations (120 KBytes) |
| ---- Job Site Photos ---- | |
|
|
Pumphouse Construction Shot (127 KBytes) |
|
|
Same ECV 250 Hp Variable Speed Controller Installed (276 KBytes)
|
|
|
250 Hp, 2500 GPM Variable Speed Booster Fire Pump (252 KBytes)
Motor and Pump Driven by ECV Controller |
|
|
3750 GPM Flow Test (77 KBytes) |
| 125 Hp ECVRT-125-46 Dual Source Transfer Switch Variable Speed Controller with Primary Reactor Reduced Voltage Starting in By-Pass Mode with 5% Line Reactor and D.C. Link Reactor in NEMA 12 Enclosure Driving Vertical Turbine Deep Well Dual-Uses Fire and Process Water Pump - for - Multi-Building Commercial and Residential Development. |
|
| ---- Factory Build Photos ---- | |
| |
Three Bay - Closed Door View (116 KBytes)
Three Bay - Closed Door Larger View (409 KBytes) |
| |
Three Bay - Open Door View (240 KBytes) Three Bay - Open Door Larger View (223 KBytes) Three Bay - Open Door Larger View (475 KBytes) |
| ---- Job Site Photos ---- | |
|
|
Controller and Generator Building (Looking NW) (135 KBytes) |
|
|
ECVRT in Generator Building (99 KBytes) |
|
|
ECVRT Fire Pump Controller and Gen-Set (83 KBytes) |
|
|
DPX-0-1-11 Duplexer and Pump Alternator in Generator Building   (152 KBytes) |
|
|
Fire Pump Vault with Hollow Shaft Vertical Turbine Pump Motor, with Main Relief Valve and Test Header Valves (and broom) (187 KBytes) |
|
|
Fire Pump Vault with Hollow Shaft Vertical Turbine Pump Motor, with Stainless Junction Box and Pressure Switch Box (Red) (184 KBytes) |
| ---- Job Site Fact Sheet ---- Thomas R. Harley Architects -- Indiana, Pennsylvania Geoffrey S. Miller, P.E. - System Designer |
|
|
|
Breeze Point Landing Energy System Fact Sheet (41 KByte PDF) |
| 125 Hp ECV-125-46 Full Voltage Starting in By-Pass Mode With 5% Line Reactor and D.C. Link Reactor in NEMA 12 Enclosure Driving Vertical Turbine Deep Well Fire and Domestic Water Pump - for - Multi-Building Medical Campus. |
|
| ---- Factory Build Photos ---- | |
| |
Closed Door View (176 KBytes)
With Air-to-Air NEMA 12 Heat Exchanger on Right Hand Side Wall |
| |
Open Door View (139 KBytes) Open Door View (335 KBytes) |
| ---- Job Site Photos ---- |
|
|
|
Exterior View of Air Conditioned Fire Pump Pumphouse (292 KBytes)
Pad Mount Transformer and A/C Condensing unit on Left Side of Pumphouse |
|
|
125 Hp, 750 GPM Vertical Hollow Shaft Motor Well Pump (108 KBytes)
Motor and Pump Driven by ECV Controller in background |
| 60 Hp ECVRTZ Dual Source -- Transfer Switch Controller With Primary Reactor Reduced Inrush Starting in Bypass Mode With 5% Line Reactor in NEMA 12 Enclosures Driving Horizontal Booster Pumps in Primary & Backup Pump Mode Fire Water and Domestic Water Booster Pumps - for - Large Shopping Center. |
|
| ---- Factory Build Photos ---- | |
| |
Model ECVRTZ - 60 Hp -- Closed Door Picture (248 KBytes)   Variable Speed Transfer Switch Fire Pump Controller |
| |
Close up of Model ECVRTZ Control and Drive Bays(269 KBytes)   With Primary Reactor Starting in the "By-Pass" mode -and- with 5% Line Reactor |
| ---- Pump Factory Build Photos ---- | |
|
|
ECVRTZ - 60Hp & 30 Hp Transfer Switch Controllers (271 KBytes)
Four Pump Skid Mount Package - 60 Hp + 60 Hp + 30 Hp Controllers |
|
|
ECVRTZ - 30 and 60 Hp Transfer Switch Controllers (245 KBytes)
Four Pump Skid Mount Package - 30 Hp Controller on Near End |
| ---- Job Site Photos ---- | |
|
|
ECVRTZ - 30 and 60 Hp Transfer Switch Controllers (311 KBytes)
Looking Toward the Two 30 Hp Vertical Domestic and Fire Water Pumps |
|
|
ECVRTZ - 30 and 60 Hp Transfer Switch Controllers (84 KBytes)
Looking Toward the Two 60 Hp Horizontal Split Case Fire Pumps |
|
|
Pump House View with Doug Hutcheson (310 KBytes)
(Hutcheson Engineering Products; Inc, Omaha, Nebraska) Looking Toward the Two 60 Hp Fire Pumps Protecting a new 2 Million Square Foot Shopping Mall near Des Moines, Iowa. |
About Master Control Systems
|
About Fire Pump Controllers
| Engineering
Information
Literature Request Email
| Master
Reps
| Other Links